Leave Your Message

China 1.60 mm Square Terminal Female/Male - Reliable Suppliers & Factory for Quality Circuit Connections

Connectivity: Our terminals, manufactured in China by trusted suppliers and factories, guarantee secure wire connections that promote stable and reliable circuit operation.

,

Fixability: These terminals are designed to hold wires securely in place, preventing loosening and ensuring the safety of your circuits.

,

Detachability: Engineered for easy detachment, our terminals simplify maintenance and wire replacement, making them a smart choice for any installation.

,

Standardization: Featuring standardized designs, our terminals are compatible with various devices and circuits, ensuring versatility and ease of use.

,

Diversity: We offer a diverse array of terminal types and configurations, all sourced from China's top suppliers and factories, to meet the unique needs of your circuits and equipment.

    Female Technical Features

    Contact Material: Copper alloy +SUS
    Wire Size Range: 0.35-0.50mm², 0.50-0.75mm²
    Current Carrying Capacity: up to 15 Ampere (@ 80°C ambient temperature)
    Total Temperature Range: -40°C … +130°C (tin plated)
    Insertion Force: 3-8N
    Extraction Force: 1-5N
    Product Drawing: 922-160-XXXX
    Product Specification: PS-922-160
    Application Specification: AP-922-160
    * The option which extraction tool is the right tool for the application is dependent on the assembly of the contact and the connector.
    1.60 mm Square Terminal Female 2
    Standard Receptacle Contact Wire Size Range mm² Insulation Diameter mm² Part Number Material Finish Mating Tab Contact
    Unsealed 0.35-0.50 1.1-1.4 922-160-1001 Copper alloy +SUS Tin 932-160-xxxx
    Unsealed 0.50-0.75 1.4-2.1 922-160-5002 Copper alloy +SUS Selective Gold 932-160-xxxx
    Contact Material: Copper alloy+SUS
    Wire Size Range: 0.2-0.50mm², 0.50-1.0mm²
    Current Carrying Capacity: up to 15 Ampere (@ 80°C ambient temperature)
    Total Temperature Range: -40°C … +130°C (tin plated)
    Insertion Force: 3-8N
    Extraction Force: 2N
    Product Drawing: 922-160-XXXX
    Product Specification: PS-922-160
    Application Specification: AP-922-160
    * The option which extraction tool is the right tool for the application is dependent on the assembly of the contact and the connector.
    1.60 mm Square Terminal Female 4
    Standard Receptacle Contact Wire Size Range mm² Insulation Diameter mm² Part Number Material Finish Mating Tab Contact
    Unsealed 0.2-0.5 922-160-6011 Copper alloy+SUS Tin 932-160-xxxx
    Unsealed 0.5-1.0 922-160-6012 Copper alloy+SUS Tin 932-160-xxxx
    Unsealed 0.5-1.0 922-160-6013 Copper alloy +SUS Tin 932-160-xxxx

    Male Technical Features

    Contact Material: Copper alloy+SUS
    Wire Size Range: 0.35-0.50mm², 0.50-0.75mm²
    Current Carrying Capacity: up to 15 Ampere (@ 80°C ambient temperature)
    Total Temperature Range: -40°C … +130°C (tin plated)
    Product Drawing: 932-160-XXXX
    Product Specification: PS-932-160
    Application Specification: AP-932-160
    * The option which extraction tool is the right tool for the application is dependent on the assembly of the contact and the connector.
    1.60 mm Square Terminal Male 2
    Standard Receptacle Contact Wire Size Range mm² Insulation Diameter mm² Part Number Material Finish Mating Rec Contact
    Unsealed 0.35-0.50 1.15-1.6 932-160-1001 Copper alloy+SUS Tin 922-160-xxxx
    Unsealed 0.50-0.75 1.4-2.1 932-160-1002 Copper alloy+SUS Tin 922-160-xxxx

    Application

    Electronic Equipment Connection

    Terminals are used to connect wires and cables in electronic devices such as computers and home appliances, ensuring reliable circuit connections.

    Control & Distribution Cabinets

    In industrial systems, terminals connect wires in control and distribution cabinets, facilitating electrical equipment wiring.

    Power Equipment Connection

    Terminals ensure safe connections in power systems for equipment like transformers and contactors.

    Instrument Connection

    Terminals connect instruments like sensors directly to control systems efficiently and securely.

    Communication Equipment

    Terminals link communication devices like routers and base stations, ensuring proper signal transmission.

    Frequently Asked Questions

    1. What is the current carrying capacity of these terminals?
    These square terminals can safely carry up to 15 Ampere at an ambient temperature of 80°C.
    2. What is the standard operating temperature range?
    The total temperature range for the tin-plated terminals is between -40°C and +130°C, making them highly resilient in varied environments.
    3. What high-quality materials are used for the contacts?
    The contacts are manufactured using a durable combination of Copper alloy and SUS (Stainless Steel).
    4. Are these standard receptacle contacts sealed or unsealed?
    The standard receptacle contacts detailed in these specifications are designed as unsealed components.
    5. How do I determine the correct extraction tool?
    The appropriate extraction tool depends on the specific assembly of the contact and the mating connector. Please refer to the application specifications for exact tooling requirements.