Leave Your Message

6.30 mm Square Terminal Female - Reliable Connectivity from China Suppliers and Factory for Your Circuit Needs

Connectivity: Our terminals offer reliable connections, ensuring stable circuit functionality for your devices. As a leading supplier from China, we prioritize quality in every component.

,

Fixability: Designed for security, our terminals firmly fix wires in place, preventing any looseness and enhancing circuit safety, making our factory's products a trusted choice.

,

Detachability: Easy to detach, our terminals simplify maintenance and wire replacement, aligning with the needs of modern equipment in various industries.

,

Standardization: With standardized designs, our terminals guarantee compatibility across multiple devices and circuits, making us a top choice among suppliers in China.

,

Diversity: Our factory provides a diverse range of terminal types and forms to meet different equipment and circuit requirements, accommodating a wide variety of applications.

    Female Technical Features

    • Contact Material: Copper alloy+SUS
    • Wire Size Range: 2.50-4.00 mm², 4.00-6.00mm²
    • Current Carrying Capacity: up to 36 Ampere (@ 80°C ambient temperature)
    • Total Temperature Range: -40°C … +130°C
    • Insertion Force: 10N Max
    • Extraction Force: 5N Min
    • Product Drawing: 922-630-XXXX
    • Product Specification: PS-922-630
    • Application Specification: AP-922-630
    * The option which extraction tool is the right tool for the application is dependent on the assembly of the contact and the connector.
    6-30 mm Square Terminal Female
    Standard Receptacle Contact Wire Size Range mm² Insulation Diameter mm² Part Number Material Finish Mating Tab Contact
    Unsealed 2.50-4.00 3.4-4.4 922-630-1001 Copper alloy+SUS Tin 923-580-xxxx
    Unsealed 4.00-6.00 3.4-4.3 922-630-1002 Copper alloy+SUS Tin 923-580-xxxx
    Unsealed 2.50-4.00 3.4-4.4 922-630-2001 Copper alloy+SUS Silver 923-580-xxxx
    Unsealed 4.00-6.00 3.4-4.3 922-630-2002 Copper alloy+SUS Silver 923-580-xxxx
    Unsealed 4.00-6.00 3.4-4.3 922-630-4001 Copper alloy+SUS Selective Silver 923-580-xxxx
    • Contact Material: Copper alloy+SUS
    • Wire Size Range: 1.00-2.50mm², 2.50-4.00mm², 6.00mm²
    • Current Carrying Capacity: up to 36 Ampere (@ 80°C ambient temperature)
    • Total Temperature Range: -40°C … +130°C
    • Insertion Force: 13N Max
    • Extraction Force: 2N Min
    • Product Drawing: 922-630-XXXX
    • Product Specification: PS-922-630
    • Application Specification: AP-922-630
    * The option which extraction tool is the right tool for the application is dependent on the assembly of the contact and the connector.
    6-30 mm Square Terminal Female
    Standard Receptacle Contact Wire Size Range mm² Insulation Diameter mm² Part Number Material Finish Mating Tab Contact
    Unsealed 1.00-2.50 2.1-3.0 922-630-1011 Copper alloy+SUS Tin 923-580-xxxx
    Unsealed 2.50-4.00 3.4-4.4 922-630-1012 Copper alloy+SUS Tin 923-580-xxxx
    Unsealed 6.00 4.3 922-630-1013 Copper alloy+SUS Tin 923-580-xxxx

    Applications

    Electronic Equipment Connection

    Terminals are widely used for connecting wires and cables in electronics such as computers, mobile phones, and household appliances to ensure circuit reliability.

    Control & Power Distribution Cabinets

    Terminals in industrial control systems connect wires in control and power distribution cabinets, facilitating electrical connections and wiring.

    Power Equipment Connection

    Terminals connect power equipment like transformers, circuit breakers, and contactors in power systems, ensuring safe and reliable operations.

    Instrument Connection

    Various instruments, such as temperature and pressure sensors and flow meters, are connected to control systems using terminals.

    Communication Equipment

    Terminals connect communication devices, including routers, switches, and base stations, ensuring effective signal transmission.

    Frequently Asked Questions (FAQ)

    What is the current carrying capacity of these female terminals?
    These female technical terminals can carry up to 36 Ampere at an ambient temperature of 80°C.
    What materials are used to manufacture the contacts?
    The contacts are manufactured using a highly durable combination of Copper alloy and SUS.
    What is the operating temperature range for these products?
    The total operating temperature range is quite broad, functioning reliably from -40°C up to +130°C.
    What wire size ranges are supported?
    Depending on the specific part number, supported wire sizes include ranges from 1.00-2.50 mm², 2.50-4.00 mm², 4.00-6.00 mm², and up to 6.00 mm².
    Where are these standard receptacle contacts typically applied?
    They are widely utilized across multiple industries, including electronic equipment connections, control and power distribution cabinets, power equipment, instrument connections, and communication devices.
    What are the insertion and extraction forces required?
    The insertion force is generally between 10N and 13N Max, while the extraction force ranges from 2N to 5N Min, depending on the exact connector series.